High-power electric vehicle (EV) charging is changing how energy is measured. Passenger vehicles typically charge in shorter sessions, but heavy-duty vehicles (HDVs) can require sustained high-power charging over longer periods, altering the thermal and electrical conditions inside the charger.
That shift makes dc energy metering more difficult. Measurement accuracy has to remain stable at high current and during low-current top-up periods, despite thermal drift. Billing data must also stay secure and reliable in connected charging environments.
Florent Balboni, global product manager for EV charging at LEM, works on energy measurement technologies for dc charging applications. In this interview, he discusses how charging profiles change for heavy-duty vehicles, why accuracy becomes more difficult at higher power levels, and what engineers should consider when integrating dc meters into high-power EV chargers.
Here’s what he has to say…
How do heavy-duty charging profiles differ from passenger EV charging, and what measurement challenges do they introduce?
For passenger EV charging, the session generally starts with a peak current, and then the current tapers off as the battery approaches full charge. Charging sessions are often short and intermittent, allowing the EV charger to cool down between charges.
For HDVs, on the other hand, the utilization rate needs to be very high. HDV sites have high upfront infrastructure and ongoing running costs, and these need to be offset.
The dc charger must, therefore, be capable of charging at maximum power, delivering high levels of power for extended periods. This means more stress on the components, along with higher thermal constraints, making reliability essential.
In terms of challenges for current and energy measurement, prolonged high current can lead to thermal drift in measurement components, which can affect accuracy. Stable and accurate measurement is therefore required over long periods of continuous load and high temperatures.
Why does accurate dc energy metering become more difficult as EV charging power approaches megawatt levels?

A dc energy meter in a fast-charging system measures energy delivered between the charger and vehicle, supporting billing accuracy and connected charging data.
As charging power approaches megawatt levels, accurate energy metering becomes more of a challenge, primarily because of electrical and thermal effects.
At higher currents, even small measurement errors can accumulate into large discrepancies, which has a knock-on effect on billing and efficiency.
Megawatt-scale charging involves currents of several kiloamps at high dc voltages. Measurement devices and components are subjected to high temperatures, which can result in thermal drift, while electromagnetic interference can also be an issue.
Why does low-current measurement accuracy matter in dc fast charging systems designed for high peak currents?
Consider a bus or electric truck depot. Drivers using these facilities typically want to charge at high power at night, ready for the morning.
However, it doesn’t take all night to charge the vehicle, and once charged, it remains connected. As a result, the charger must continue supplying energy at low levels to keep the vehicle topped up. So, not only do high currents have to be managed, but low currents too. Maintaining accuracy here is also essential.
Newer dc energy meters are designed to measure a wide current range from the same device, from very low current levels to high peak currents. For charging operators, this helps support accurate energy measurement across the full charging cycle, including prolonged high-power charging and lower-current top-up periods. Certification to legal metrology standards, such as the Measuring Instruments Directive (MID) and Eichrecht, can also support billing accuracy and compliance.
How do component heating and temperature gradients affect dc energy measurement accuracy?
In a laboratory with standard conditions and long, well-arranged cables, constraints are limited. In real chargers, you encounter relays, fuses, cooling systems, airflow, and unexpected mounting positions: the real world of power electronics.

Dd energy meters used in high-power EV chargers must measure accurately across wide current ranges while fitting into constrained power electronics layouts.
Both environments matter. Products must be certified according to standards, but they also need to be designed and tested to operate reliably in constrained real-world conditions.
Thermal effects and temperature gradients can have a significant effect on performance. If the product is not properly designed, accuracy and reliability issues can occur.
To protect energy meters from thermal effects, some designs use built-in software algorithms that compensate for thermal imbalance. If one part of the product becomes a hotspot while another is cooled, for example by a liquid-cooled cable, these algorithms can compensate for the imbalance.
What system-level design considerations matter when integrating dc meters into high-power EV chargers?
When integrating any component, such as a fuse, relay, or energy meter, engineers inherit some constraints from the manufacturer.
Manufacturers typically provide recommendations for mounting and busbar fastening. The key point is that an energy meter should not create weaknesses in the system.
This is especially important for thermal effects in high-power chargers. When designing such a system, engineers usually balance two goals: maximum power and maximum allowable temperature. At some point, the system reaches thermal limits and begins derating, reducing power to avoid overheating.
Energy meters with high operating-temperature limits, low insertion losses, and suitable busbar-temperature ratings can help avoid additional thermal stress in the charger. This means they do not generate significant power losses or create hotspots.
The derating of the overall charger should not be caused by the energy meter. Ideally, the meter does not introduce additional thermal issues into the system.
What cybersecurity and data integrity considerations matter for dc energy meters in connected EV charging systems?
Secure data transfer is essential, particularly as cybersecurity risks become more prevalent and severe. It only takes a single incident, and subsequent negative headlines, to negatively impact public perception and undo much of the work done to encourage EV adoption. Continuing the upward trajectory of recent years requires consumers to trust the technology.
Cybersecurity is critical and especially important for energy meters because of the nature of the data they collect. This data is used for billing, so it must be protected. It must be authenticated and trusted for financial transactions.
Then there is the Cyber Resilience Act, which addresses how we protect against and prevent such attacks. This requires manufacturers to ensure that an effective framework is in place to continually identify and mitigate cyber threats in the design and throughout the lifecycle of their products.
Some energy meters now support field software updates, allowing charger manufacturers to improve functions or strengthen protection without replacing hardware. This can help support proactive security maintenance over the product lifecycle.
Filed Under: Charging, Featured Contributions, Q&As