An electric vehicle (EV) traction inverter can drive unwanted current through the motor bearings. Its switching creates voltage on the motor shaft, even without a direct electrical connection between the windings and rotor. If the voltage across a bearing exceeds the insulating capability of its lubricant film, a brief electrical discharge pits the bearing surfaces. Repeated discharges accelerate wear and shorten bearing life.
This article explains how silicon carbide (SiC) inverter switching affects bearing currents in EV traction motors. It also discusses how engineers limit damage while retaining SiC’s efficiency and power-density advantages.
How shaft voltage builds
The inverter’s three phase outputs drive currents in the motor windings. This creates the rotating magnetic field that produces torque. Switching also generates a voltage component shared by these outputs, known as common-mode voltage. Capacitance between the windings and rotor couples part of this changing voltage to the shaft. As shown in Figure 1, rotor-to-stator-core and bearing capacitances complete a voltage divider that determines how much voltage appears across the bearings.

Figure 1. Parasitic capacitances couple common-mode voltage (UCM) to the motor shaft, producing voltage across the bearings (UB). (Image: Bleicher et al., e+i Elektrotechnik und Informationstechnik, CC BY 4.0)
A bearing contributes capacitance to this divider when a lubricant film separates its rolling elements from the raceways. Voltage changes produce capacitive current without film breakdown. If the film breaks down, stored energy discharges locally through a process known as electrical discharge machining (EDM). Importantly, speed and temperature shift that breakdown threshold.
Common-mode current can also generate magnetic flux that drives a circulating current through the shaft, both bearings, and the frame. Depending on the drivetrain design, the reduction gearbox provides another path from the shaft to the housing, putting gearbox bearings at risk.
What fast SiC edges change
These current paths also exist in drives using silicon insulated-gate bipolar transistors (IGBTs). However, SiC MOSFETs support faster switching by avoiding the stored-charge effects that slow IGBT turn-off.
Because capacitive current follows i = C·dv/dt, steeper voltage edges produce larger current pulses for the same capacitance. These edges contain more high-frequency energy, increasing the risk of resonance in the inverter-to-motor network. The drive’s frequency response affects how much shaft voltage these edges produce.
Beyond edge speed, switching frequency and bus voltage affect bearing stress, with a higher switching frequency producing more common-mode transitions per second. Raising the bus voltage from 400 V to 800 V doubles the common-mode voltage swing for the same inverter topology and modulation.
Protecting bearings while retaining fast switching
Slowing the switching edges by increasing gate resistance reduces dv/dt at the expense of increased switching loss. Other approaches reduce common-mode voltage and divert current away from the bearings. Table 1 compares the different options.
Changing the modulation does not require additional power hardware. AZSPWM replaces zero vectors, which apply no voltage between motor phases, with pairs of opposing active vectors. In a two-level inverter, this strategy reduces peak common-mode voltage to one-third of the conventional space-vector PWM value. After implementation, engineers must check the resulting current distortion and switching losses across the torque-speed range.
Although a properly designed common-mode filter reduces bearing voltage, incorrect sizing risks amplifying it through resonance. An EV motor-drive study at 400 V and 50 kHz found that a 13 mH filter reduced measured bearing voltage from 7.9 V to 3.1 V. A 3 mH filter instead raised it to 13 V by shifting the system’s resonance close to the switching frequency.
Conductive-fiber rings or brushes complement filtering by diverting shaft current to the housing through the bypass path shown in Figure 2. Their effectiveness depends on reliable contact throughout service life.

Figure 2. The shaft-grounding path (ZG) provides a low-impedance connection between the shaft and housing, reducing voltage across the bearings. (Image: Bleicher et al., e+i Elektrotechnik und Informationstechnik, CC BY 4.0)
Insulated bearings, such as those shown in Figure 3, increase impedance in the bearing-current path. Hybrid bearings use ceramic rolling elements to impede current through the rolling contacts. Notably, neither approach eliminates shaft voltage. Engineers must instead check whether current shifts to another bearing or the gearbox.
Validating the design

Figure 3. SKF INSOCOAT bearings use an electrically insulating coating on the inner or outer ring to impede current through the bearing. (Image: SKF)
In the filter-sizing study discussed earlier, researchers recorded 238 breakdown discharges per minute with the 3 mH filter. They recorded none with the 13 mH filter under the same test conditions.
Those results apply to the tested drive and operating conditions. Engineers verify mitigation on their own drivetrain by measuring bearing voltage and discharge current. They use the inverter’s common-mode waveform to relate discharges to switching.
Bearing-current measurements cover the intended operating range, with particular attention to speed and temperature. Durability testing then determines whether grounding contacts maintain an effective bypass as they wear.
Summary
SiC’s fast edges increase bearing risk, but the resulting shaft voltage depends on the drive’s common-mode voltage and frequency response. Engineers limit bearing stress while retaining fast switching by reducing common-mode excitation with modulation and a correctly sized filter, then giving residual current a controlled path away from the bearings. Measurement on the complete drivetrain, rather than dv/dt alone, shows whether those measures hold across the operating range and whether current has shifted to the gearbox.
References
- Research on Analysis and Suppression Methods of the Bearing Current for Electric Vehicle Motor Driven by SiC Inverter, MDPI
- Bearing insulation prevents electrical current damage, Evolution Technology Magazine
- How Does a Gate Driver Work, Infineon
- Evaluating the Effectiveness and Longevity of Grounding Bearings in Mitigating EDM Bearing Currents in Electric Machines and Drive Systems, Springer
- Electrically Insulated Bearings for EV Motors: How They Reduce Failures, TFL
- dv/dt Simulation Scenario 1: SiC Drive, dvdtfilter
- Characterization and Analysis of Bearing Currents and Shaft Voltages in SiC Inverter Driven PM Machine, IEEE Xplore
- Review on Tribological and Vibration Aspects in Mechanical Bearings of Electric Vehicles: Effect of Bearing Current, Shaft
- Voltage, and Electric Discharge Material Spalling Current, MDPI
- High Voltage Spike (dV/dt) and Motor Protection Methods, VFDS
Related EEworld content
- JEDEC Publishes New Guidelines for Evaluating SiC Power Devices
- GaN and SiC Bring Higher Power Density to Electrified Powertrains
- How Motor Selection Shapes System Performance
- Optimizing EV Motor Design with Advanced Materials and AI
- The Pros and Cons of the Four Main EV Motor Configurations
Filed Under: Componentry, FAQs, Featured Contributions, Power Electronics