Thermal strategy for sustained high-load dual-motor drive units

By Oscar Collins, Editor-in-Chief | Modded | June 25, 2026

Dual-motor electric vehicles (EVs) can generate substantial torque for extended periods. However, continuous high-load operation places significant demands on the powertrain’s thermal management system.

A dual-motor EV skateboard chassis with front and rear drive units, a central battery pack, and the coolant lines linking them.

Heavy payloads, steep grades, towing applications, and prolonged highway operation increase rolling resistance and current draw. The resulting thermal load must be managed across the powertrain, from the cooling loop to the power electronics.

Under these conditions, thermal engineering becomes one of the most important factors in maintaining power output and protecting critical components. Cooling-loop design and inverter thermal management can determine how effectively a drive unit can sustain high output without thermal derating.

Modeling thermal duty cycles under load

Thermal duty-cycle modeling defines the load conditions the powertrain must support during operation. Factors such as road gradient, aerodynamic drag, rolling resistance, and total vehicle weight all affect torque demand.

Modeling worst-case thermal stress profiles starts with baseline vehicle and duty-cycle data, including payload rating, towing capacity, GVWR/GCWR, gradeability targets, and expected drive cycles. These inputs help estimate rolling resistance, current demand, and inverter heat rejection requirements during sustained high-load operation.

These calculations establish the foundation for thermal simulations that estimate heat generation rates and determine the cooling capacity required for sustained operation.

Cooling-loop fluid dynamics and heat rejection

Once the expected heat load is defined, cooling-loop design shifts to moving that heat out of the system efficiently. Most EV cooling loops rely on glycol-water mixtures because they offer a useful combination of freeze protection, corrosion resistance, and thermal performance.

The exact formulation is important. A coolant’s viscosity sets its pumping load, while thermal conductivity and specific heat capacity determine how much heat it carries away from motors and power electronics. The coolant must also be compatible with the high-voltage environment found in modern EVs.

Figure 2. External view and cross-section of a 250-kW internal permanent magnet synchronous motor cooling system. The figure illustrates how cooling-system design and CFD analysis can be used to evaluate heat rejection in high-power electric motor applications. (Science Direct)

Traditional coolants used in internal combustion engine applications typically exhibit conductivity values between 2,000 and 5,000 µS/cm. In EVs, coolant frequently operates near high-voltage components, which creates a stronger need for electrically resistive fluids.

Newer EV coolant standards, including ASTM D8566 and China’s GB 29743.2, specify conductivity limits of around 100 µS/cm. Lower conductivity helps reduce the risk of stray-current effects while supporting the safe operation of high-voltage systems.

Coolant routing, flow rate, and pressure drop then become central design considerations. Higher flow rates generally improve convective heat transfer, but they also increase pressure drop and pumping requirements.

The goal is to achieve sufficient heat rejection without introducing unnecessary parasitic losses.

Flow distribution can be just as influential. In dual-motor architectures, multiple heat-generating components typically share the same cooling network. Uneven coolant routing may create localized hot spots or temperature gradients that cause some inverter modules to approach thermal limits sooner than others.

To reduce this risk, computational fluid dynamics can identify thermal bottlenecks before physical testing begins. These simulations help optimize the coolant routing to support more stable inverter temperatures during sustained high-load operation.

Managing SiC inverter junction temperatures

The motor may generate much of the drive unit’s heat, but the inverter introduces its own thermal challenge. During sustained high-power operation, silicon carbide (SiC) devices are constantly switching and conducting current.

One of the most closely monitored parameters inside an inverter is junction temperature. This value represents the temperature at the semiconductor, which makes it a far more useful indicator of device stress than the temperature measured on the module housing or cooling plate.

Repeated heating and cooling during acceleration, regenerative braking, and extended high-load driving create thermomechanical stress inside the power module. Over time, these thermal cycles can accelerate wear within the power module, which reduces inverter reliability and shortens component life. For this reason, engineers monitor peak junction temperatures and the magnitude of thermal cycling throughout the vehicle’s operating life.

An open traction-inverter power module, showing the dies and wire bonds where junction temperature and thermal cycling determine long-term reliability. (Image: Infineon)

Thermal limits continue to expand as SiC technology matures. A recent example comes from Infineon, which introduced a 1,300-V SiC power module capable of continuous operation at junction temperatures up to 205° C. Many existing automotive SiC inverter designs are rated for continuous operation at around 175° C. That additional temperature margin gives engineers greater flexibility when designing high-performance powertrains.

Sustained high-load operation places continuous thermal stress on every major component within a dual-motor drive unit. Accurate duty-cycle modeling provides the foundation for predicting heat generation, while cooling-loop design determines how effectively that heat can be removed. Careful management of inverter junction temperatures also helps maintain efficiency, reliability, and continuous performance.

References

  • ASTM International, “ASTM D8566-24, Standard Specification for Glycol-Based Electric Vehicle Coolant with Low Electrical Conductivity,” ASTM International, West Conshohocken, PA, 2024. store.astm.org/d8566-24.html
  • Standardization Administration of China, “GB 29743.2-2025, Motor vehicle coolant, Part 2: Coolant for electric vehicles,” effective October 1, 2025.
  • Tamara Gammaidoni, Jacopo Zembi, Michele Battistoni, Giulia Biscontini, and Alessandro Mariani, “CFD Analysis of an Electric Motor’s Cooling System: Model Validation and Solutions for Optimization,” Case Studies in Thermal Engineering, Vol. 49, 2023, Article 103349. doi.org/10.1016/j.csite.2023.103349. Licensed under CC BY 4.0.
  • Infineon Technologies AG, “Infineon sets new benchmark for electric vehicle inverters and introduces first silicon carbide power module operating at 205° C,” press release, May 29, 2026.
    infineon.com/products/power/igbt/automotive-qualified-igbts/coolsic-mosfet-modules/hybridpack-drive-dc6

—
Author Bio: Oscar Collins is the editor-in-chief of Modded and runs his own auto tech blog, The Gearhead Guide. He has bylines on Auto News, Gizmodo and Global Trade Mag. Currently living in NYC, he’s always looking to write on the next exciting innovation in auto tech.

 

You might also like


Filed Under: FAQs, Thermal Management, Thermal Management System
Tagged With: coolant, FAQ, thermalmanagement
 

Next Article

← Previous Article
Next Article →


 
“ee
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EV professionals.

Tech Spotlight

  • What EV battery health data isn’t telling us
  • How ceramifying coatings protect EV battery enclosures
More Tech Spotlight

Featured Contributions

  • What EV battery health data isn’t telling us
  • How are EV battery packs designed for repairability?
  • What field failures reveal about heavy-duty e-axle validation
  • How ceramifying coatings protect EV battery enclosures
  • How has NACS evolved into the SAE J3400 EV charging standard?
More Featured Contributions

EV TECH TOOLBOX

“ee
Explore the EV Engineering Tech Toolboxes: a collection of high-impact articles that break down the latest EV design trends and technologies. Download to stay aligned with today’s evolving EV design challenges.

Learning Center

EE Learning Center

Sponsored Content

  • Converting custom materials for EV applications
  • Advantech Powers Versatile Electric Vehicle Charging Systems

EV Training Days

ev
Q&A
EV Engineering & Infrastructure
  • 5G Technology
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • EDABoard Forums
  • Electro-Tech-Online Forums
  • Engineer’s Garage
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips
  • Test and Measurement Tips
  • Contact Us

Copyright © 2026 Arrowfly LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Arrowfly
Privacy Policy | Advertising | About Us

Search EV Engineering & Infrastructure

  • News
  • Articles
    • Q&As
    • Tech Spotlight
  • Batteries
  • Charging
    • Wireless Charging
    • Vehicle-to-Grid (V2G)
  • Electrification
  • Testing and Safety
  • Learn
    • Learning Center
    • Tech Toolboxes
    • Webinars
  • Resources
    • Digital Editions
    • Diversity & Inclusion
    • Voices
  • Advertisers
    • Advertise
    • PR Submissions
    • Eblast Submissions
  • Subscribe