EV Engineering & Infrastructure

  • News
  • Articles
    • Q&As
    • Tech Spotlight
  • Batteries
  • Charging
    • Wireless Charging
    • Vehicle-to-Grid (V2G)
  • Electrification
  • Testing and Safety
  • Learn
    • Learning Center
    • Tech Toolboxes
    • Webinars
  • Resources
    • Digital Editions
    • Diversity & Inclusion
    • Voices
  • Advertisers
    • Advertise
    • PR Submissions
    • Eblast Submissions
  • Subscribe

Part II: Preparing EV charging infrastructure for V2X

By Michelle Froese | June 4, 2026

Bidirectional charging has long been discussed as a way to turn EVs into active energy assets rather than passive electrical loads. As vehicle platforms and charging systems become more sophisticated, engineers are beginning to evaluate how charging infrastructure could support energy flow between vehicles, buildings, and the grid.

Faraz Tung, Principal Solutions Engineer with SWTCH

In this interview, Faraz Tung, principal solutions engineer with SWTCH, discusses the technical barriers still limiting large-scale vehicle-to-everything (V2X) deployment, and how charging infrastructure may need to evolve as bidirectional energy systems become more viable.

Part I of this Q&A focused on EV charging infrastructure design and operational reliability. Part II examines how bidirectional charging could change future EV infrastructure design and what challenges still need to be addressed before V2X deployment can scale more broadly.

Here’s what he had to say…

As charging networks grow, what real-time data and monitoring capabilities become essential for reliability and performance?

At scale, two categories of real-time data become operationally critical. The first is electrical load visibility, understanding not just what the chargers are drawing, but how that load interacts with adjacent circuits sharing the same service. Without that broader picture, operators are flying blind on when a load rebalancing event is needed and whether the site is approaching its service limits.

The second category is connectivity and device health telemetry. Charger heartbeat data and cellular signal quality metrics are essential diagnostic signals. A brief network disconnection might be benign, or it might be the leading indicator of a broader connectivity issue affecting a group of units.

Understanding the behavioral signature of the charging network, including how stations behave during and after short disconnection events, is what separates reactive maintenance from proactive network management. Both layers of data, electrical and connectivity, need to be surfaced in a way that allows operators to correlate events and identify root causes efficiently.

What role will V2X technologies play in future EV charging infrastructure design?

The implications of V2X at scale are significant enough that they warrant a fundamental rethink of how charging sites are architected. An EV fleet with bidirectional capability is effectively a distributed, multi-gigawatt battery resource, one that can absorb excess generation, support demand response programs, and provide backup power to buildings or the grid depending on the configuration.

That shift changes the design objective of a charging site from maximizing power delivery to managing bidirectional energy flow as the primary function. Future sites will need to be designed as active grid-edge assets, with the electrical architecture, control systems, and software layers capable of orchestrating energy in both directions in response to grid signals, building demand, and vehicle state.

The infrastructure that makes sense for a simple charging use case looks quite different from what’s needed to support that kind of active energy management role.

What technical challenges must be addressed before bidirectional charging can be deployed at scale?

Scaling V2X across public and commercial networks requires solving several interdependent technical problems simultaneously.

Engineers are increasingly evaluating how charging infrastructure can be designed today to support future V2X applications.

On the protocol side, universal adoption of ISO 15118-20 is a prerequisite, without a consistent, standardized communication layer, the coordination required for grid-interactive operation breaks down. IEEE 1547 anti-islanding requirements also need to be addressed at the hardware level, and not all currently deployed inverter and charger hardware meets those standards for bidirectional grid interaction.

Battery management is another constraint. Frequent bidirectional cycling introduces degradation mechanisms that differ from typical unidirectional charging, and battery management system (BMS) algorithms need to be sophisticated enough to manage that without unacceptably shortening battery life, something vehicle OEMs are understandably cautious about.

On the security and control architecture side, a robust PKI framework is needed to authenticate and authorize bidirectional transactions at scale. Plus, the coordination challenge is non-trivial. High-latency communication across large numbers of distributed nodes, each with different state-of-charge profiles, requires control systems that can handle that complexity without introducing instability.

How should engineers approach charger and site design today to ensure future compatibility with bidirectional energy flows?

The core principle is designing for optionality. Engineers should prioritize ISO 15118-compliant hardware now, even on sites where bidirectional use cases aren’t in the immediate deployment plan. Retrofitting communication capability later is far more disruptive than specifying it upfront.

Conduit and raceway sizing should be planned with bidirectional power capacity in mind, which typically means oversizing relative to today’s unidirectional load requirements. Dc-coupled architectures, where feasible, offer cleaner integration with storage and bidirectional inverter topologies than ac-coupled alternatives.

For sites where battery storage integration is a realistic future scenario, specifying battery energy storage system (BESS)-ready inverters from the start positions the site to transition from a passive charging location to an active grid-edge asset as V2X vehicle software matures and utility programs that compensate for grid services become more widely available.

The sites that are designed with these considerations baked in today will have a meaningful cost and timeline advantage when the market and regulatory environment catch up.

 

You might also like


Filed Under: Charging, Featured Contributions, Q&As, Vehicle-to-Grid (V2G)
Tagged With: bidrectionalcharging, charging, q&a, v2g, v2x
 

Next Article

← Previous Article
Next Article →


 
“ee
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EV professionals.

Tech Spotlight

  • What EV battery health data isn’t telling us
  • How ceramifying coatings protect EV battery enclosures
More Tech Spotlight

Featured Contributions

  • What EV battery health data isn’t telling us
  • How are EV battery packs designed for repairability?
  • What field failures reveal about heavy-duty e-axle validation
  • How ceramifying coatings protect EV battery enclosures
  • How has NACS evolved into the SAE J3400 EV charging standard?
More Featured Contributions

EV TECH TOOLBOX

“ee
Explore the EV Engineering Tech Toolboxes: a collection of high-impact articles that break down the latest EV design trends and technologies. Download to stay aligned with today’s evolving EV design challenges.

Learning Center

EE Learning Center

Sponsored Content

  • Converting custom materials for EV applications
  • Advantech Powers Versatile Electric Vehicle Charging Systems

EV Training Days

ev
Q&A
EV Engineering & Infrastructure
  • 5G Technology
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • EDABoard Forums
  • Electro-Tech-Online Forums
  • Engineer’s Garage
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips
  • Test and Measurement Tips
  • Contact Us

Copyright © 2026 Arrowfly LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Arrowfly
Privacy Policy | Advertising | About Us

Search EV Engineering & Infrastructure

  • News
  • Articles
    • Q&As
    • Tech Spotlight
  • Batteries
  • Charging
    • Wireless Charging
    • Vehicle-to-Grid (V2G)
  • Electrification
  • Testing and Safety
  • Learn
    • Learning Center
    • Tech Toolboxes
    • Webinars
  • Resources
    • Digital Editions
    • Diversity & Inclusion
    • Voices
  • Advertisers
    • Advertise
    • PR Submissions
    • Eblast Submissions
  • Subscribe