Whenever an electric vehicle (EV) battery bus exceeds 400 V, it poses powertrain design challenges for engineers. One of the key design challenges is the choice of inverter topology, whether a two-level or a three-level inverter topology.
Though a three-level inverter has a higher device count, we will discuss in the article where these topologies are used in EVs, why the three-level topology lowers device voltage stress, what it costs in parts and control, and whether the efficiency gains justify it.
Where are two-level and three-level inverters used today in EVs?
The traction inverter turns dc battery power into an ac waveform that drives the motor. Every choice made within the inverter, including the topology’s voltage level, must work reliably throughout the EV’s lifetime.
When we look at Table 1, we get a clear idea of where recent powertrain technology is heading. The table shows each automaker’s bus voltage, semiconductor technology, and, where stated, inverter topology, spanning 400-V platforms like the Nissan Leaf up to the 900 V Lucid Air.

Table 1. Bus voltage, semiconductor technology, and stated inverter topology across 11 commercial EV platforms. (Image: World Electric Vehicle Journal)
Three rows give topology information beyond voltage and device technology. Tesla states level by model, two-level for Model 3 and Model Y, three-level for the Plaid. General Motors states its Ultium inverters are two-level. Volkswagen’s MEB platform names a neutral point clamped (NPC) topology, which is inherently three-level, at 400 V.
Though the other eight automakers, including Ford, Nissan, and BMW, do not directly mention the topology type, there is a broader pattern in general terms. Most inverters stay two-level, and 800 V platforms turn to three-level more often, though most commercial EVs still favor the two-level bridge for its simplicity.
What changes when an inverter goes from two-level to three-level?
A two-level bridge switches each phase directly between the positive and negative dc rails, so every switch has to block the full bus voltage on its own. A three-level bridge splits the bus in half before it reaches the switches, so each device sees roughly half the stress for the same total bus voltage.
The two topologies are shown side by side in Figure 1, six switches on the two-level side against 12 on the three-level side.

Figure 1. Six-switch two-level bridge compared with 12-switch three-level neutral point clamped bridge, showing the split dc bus that halves device blocking voltage. (Image: Energies, MDPI)
Table 2 shows two Infineon IGBTs, one rated at 650 V for a three-level inverter and the other at 1200 V for a two-level inverter. Both inverter topologies are meant to serve an 800-V, 125-kW drive. The voltage ratings of the IGBTs indicate that, for a three-level inverter, the IGBT needs to be rated at only half the voltage of a two-level inverter.

Table 2. Data sheet characteristics for a 650-V IGBT module used in a three-level design and a 1200-V IGBT module used in a two-level design, both rated at 450 A, 300 V, 125° C for an 800-V, 125-kW drive. (Image: Chalmers University of Technology)
By splitting the bus voltage in two, engineers achieve more than just selecting a lower-voltage switch. It also cleans up the output waveform because the three-level output inherently has fewer harmonics than the two-level output. Lower harmonic distortion can also reduce filtering requirements and lower dv/dt stress on the motor and other downstream components.
Keep in mind that the lower harmonic distortion does not come free. Going from six switches to 12 means going from six gate drivers to 12, plus the added control logic needed to keep the neutral point balanced. But we discuss this tradeoff in the next section.
The clamping diodes also put an additional burden on the three-level inverter. The reverse recovery of those diodes adds switching loss that the two-level bridge does not have to absorb. The three-level design also spreads that loss unevenly across its switches, creating an asymmetrical temperature distribution that a two-level bridge does not have to manage.
Does the added complexity of a three-level inverter pay off?
The mechanism and the added cost point towards a natural question. Does splitting the bus actually cut losses enough to justify the extra complexity?
A simulated comparison across three topologies, shown in Figure 2, provides a direct answer. Alongside the two-level bridge are the two three-level variants built in the same way as the NPC design in Figure 1. These are active neutral point clamped (ANPC) and the T-type design.

Figure 2. Simulated conduction and switching loss for two-level, three-level active neutral point clamped, and three-level T-type inverters at 800, 1000, and 1200 V. (Image: World Electric Vehicle Journal)
At 800 V, the two-level bridge dissipates 826.8 W total, split into 693.4-W conduction loss and 133.4-W switching loss. The ANPC design cuts that to 634.0 W, and the T-type design goes even lower at 573.3 W.
Both three-level designs also show lower losses than the two-level topology at 1000 and 1200 V under the same simulation parameters. Here, we can see an interesting pattern. At 800 V, T-type saves about 31% of what the two-level bridge loses. At 1200 V, it achieves a saving of about 40%.
The simulation assumes a perfectly balanced neutral point with no active balancing controller. The doubled switch count is already a sign of the extra control effort required, so the real benefit in production depends on how well that balance is achieved.
Summary
At first glance, three-level inverters have more components than two-level inverters. But the key advantage is reduced losses, with the benefit increasing at higher voltages. The best-performing three-level design, the T-type topology, reduces total inverter loss by about 31% at 800 V and about 40% at 1200 V.
However, these results assume a perfectly balanced neutral point without an active controller. Under that assumption, the design payoff is strongest at 800 V and above. At lower voltages, the results tend to favor a two-level topology for its greater simplicity.
References
- Powertrain in Battery Electric Vehicles (BEVs): Comprehensive Review of Current Technologies and Future Trends Among Automakers, World Electric Vehicle Journal
- Electro-Thermal, EMI and Reliability Assessment of Post-800 V Traction Inverter Topologies, World Electric Vehicle Journal
- Investigation of an ANPC Inverter in Electrified Vehicles, Chalmers University of Technology
- A Review of DC-AC Converters for Electric Vehicle Applications, Energies, MDPI
EEworld Online related content
- What are the software and control challenges when maximizing EV traction drive inverter efficiency?
- How modular, high-power SiC traction inverters could advance electrification — beyond cars
- How semiconductor materials affect EV power electronics?
- What’s the difference between an IGBT and an IGCT?
- What are the basic multilevel inverter topologies?
- What is driving development of EV inverters?
Filed Under: FAQs, Featured Contributions, Inverter, Power Electronics