A 400-V-class dc fast charger cannot directly charge an 800-V electric vehicle (EV) battery when its maximum output falls below the pack voltage. Driving current into the pack requires the source voltage to exceed the battery’s by enough to overcome drops along the charging path. To achieve this, the EV boosts the incoming voltage or reconfigures the pack into lower-voltage sections.
This article compares dedicated dc/dc converters with systems that reuse the traction motor and inverter to raise voltage. It also explains how pack reconfiguration avoids voltage boosting and why these design choices impact charging performance.
Voltage compatibility and charging power
Although voltage boosting enables charging, the process itself does not increase the station’s available power. In fact, the converter delivers less power to the battery than it draws from the station because conversion losses dissipate as heat.
Transferring 150 kW requires 375 A at 400 V, compared with 187.5 A at 800 V. At equal conductor resistance, doubling the current quadruples I²R loss in the charging cable and inlet. Boosting leaves the higher current on the charger side, where the station’s current limit still caps charging power.
Dedicated dc/dc hardware
The EV’s converter imposes a second power ceiling. A dedicated booster connects between the charging inlet and battery, with a power stage sized independently of the traction motor. This configuration adds mass and cost, while its cooling must support sustained charging.
As shown in Figure 1, the 2025 Porsche Taycan includes a standard 150-kW dc/dc converter for charging at 400-V stations. On 800-V infrastructure, the vehicle accepts up to 320 kW under ideal conditions. Yet even if a 400-V station offers more power, the converter still restricts charging to 150 kW.

Figure 1. The 2025 Porsche Taycan uses an onboard dc/dc booster to support charging at 400-V stations. (Image: Porsche)
A converter’s usable power also depends on cooling. Vicor’s NBM9280 non-isolated onboard dc/dc module doubles the charging input voltage with a fixed 2:1 ratio (the station’s output tracks approximately half the pack voltage). Vicor quotes 99% peak efficiency, though that figure does not describe losses throughout a charging session. For illustration, an onboard converter receiving 150 kW dissipates 4.5 kW as heat at 97% efficiency. Its cooling system removes that heat to keep component temperatures safely within their operating limits.
Reusing the motor and inverter
Reusing the drivetrain generates conversion losses in the motor and inverter. As shown in Figure 2, Hyundai’s Electric-Global Modular Platform (E-GMP) uses these rear-drive components to boost 400-V charging input to pack voltage. In motor-based boost converters, the windings function as inductors, while the inverter switches control energy transfer to the battery.

Figure 2. Hyundai’s E-GMP reuses the traction motor and inverter for 400-V-to-800-V boost conversion (top), while the alternative architecture uses a separate onboard dc/dc charging stage (bottom). (Image: Hyundai Motor Group)
The windings’ inductance limits how quickly current changes during inverter switching, with lower inductance producing greater ripple for the same applied voltage and switching timing.
In designs that feed charging current through the motor’s neutral point, zero-sequence inductance limits switching ripple in the current component shared equally by all three windings. Interleaving the inverter legs’ switching partially cancels their ripple contributions, reducing ripple in the charger current.
Because charging current through the motor windings may also produce unwanted torque, the controller must keep the rotor stationary. As shown in Figure 3, a simulation with a 250-A charging current produced torque peaking at 20 N·m, or 12.5% of the motor’s rated torque, when rotor-position control was disabled. With control active, the inverter injected compensating phase currents to hold the rotor at its initial position.

Figure 3. Simulated charging behavior with rotor-position control active and disabled. Compensating phase currents hold the rotor at its initial position while control remains active. (Image: Rizzoli et al.)
Alongside charging-specific control, some implementations of drivetrain-integrated boosting require additional hardware. Hofer Powertrain’s integrated booster, for example, adds a dc filter and junction box, supporting 150-kW charging from a drive unit rated for 120 kW continuous propulsion. Importantly, engineers need to validate charging-mode performance separately, including winding and inverter temperatures during stationary operation.
How the choices affect charging
A third approach avoids the voltage-raising stage by reconfiguring the battery into lower-voltage sections during charging. This shifts the design priorities to pack switching and battery management. Table 1 compares the engineering requirements of all three approaches.
The Porsche Macan reconfigures its pack to charge at 400-V stations without a booster. A high-voltage switch divides its 800-V pack into two nominally 400-V banks. The system first balances their states of charge if needed, then charges both simultaneously. Porsche quotes up to 135 kW at 400-V stations and 270 kW at 800-V stations. The corresponding 10 to 80% charging times are approximately 33 and 21 minutes.
Notably, doubling peak power does not halve charging time, as average power over the session determines how quickly the battery charges. For the Macan, 400-V charging remains slower even without booster losses. Design comparisons require charging curves and continuous thermal ratings, with efficiency maps showing converter losses across operating conditions.
Summary
An 800-V EV requires voltage conversion or pack reconfiguration to charge from 400-V infrastructure. The lower power limit of the station or vehicle sets the charging-power ceiling. Battery charge acceptance may reduce power further as charging progresses. As discussed, an EV’s peak 800-V rating does not establish its 400-V performance across a charging session.
References
- Terra 54/54HV Charger Installation Manual (NAM Version), ABB
- Optimal Balance Between Performance and Range, Porsche
- The New 2025 Porsche Taycan Models, Porsche
- Solving 400V/800V EV Fast-Charging Compatibility, Vicor
- Realizing New EV Lifestyles: 5 Advantages of the E‒GMP, Hyundai Motor Group
- High-Voltage Booster, Hofer Technology
- Power Topology Considerations for Electric Vehicle Charging Stations, Texas Instruments
- Integrated Boost-Converter for 400 V – 800 V Fast-Charging Compatibility, 2022 Second International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)
- Power Transfer from 400V Charging Piles to 800V Electric Vehicles Using Motor Winding and Inverter, IEEE Xplore
- Super Twisting Sliding Mode Control for High-Efficiency and Fast Charging of EVs Using Current-Fed Resonant Converter: 400 V and 800 V Validation, ScienceDirect
- Integrated DC Boost Charger in Post-800V Architecture with Open-End Winding Machine – Magnetic-Domain Modelling and Torque Analysis, SAE
Related EEWorld content
- How Do Onboard Chargers Differ Between 400 and 800-V EV Architectures?
- How High-Power DC Fast Chargers Manage Heat and Impact EV Batteries
- How to Select a DC-Link Capacitor for EV Fast Chargers
- Why High-Power DC EV Chargers Require Liquid Cooling Systems
- New Liquid-Cooled Power Modules Enter Production for High-Power EV Chargers
Filed Under: Charging, FAQs, Featured Contributions