Electrified platforms continue to advance, placing increased focus on battery safety at the system level. While much of the focus in electric vehicles (EVs) is placed on thermal management and battery management systems (BMS), alternative approaches are emerging that integrate passive safety mechanisms directly within battery enclosures.

Exploded view of ENEROC’s lithium battery system showing integrated components, including the built-in fire suppression system positioned within the battery enclosure.
One such approach is the use of built-in fire suppression systems embedded within lithium battery packs. These systems are designed for electrified equipment applications, such as forklifts, where compact, enclosed battery systems create similar safety considerations to those found in EV architectures.
ENEROC USA has developed lithium battery systems that integrate a Flexible Temperature-Sensing Self-Activating Fire Extinguishing Device directly within the battery enclosure. The technology is currently suitable for lithium batteries for forklifts, Class I, II, and III, including very narrow aisle (VNA) trucks.
“The device features a temperature-sensitive tube filled with a clean extinguishing agent, such as perfluorohexanone or heptafluoropropane,” explains Sandro Pagliarulo, CEO at ENEROC USA. “When the surrounding temperature reaches a critical threshold (110° C / 230° F, ±10%), the tube automatically ruptures to release the agent and suppress the fire within seconds. The system is reliable and leaves no residue or pollution.”
This product addresses the critical safety issue of fire hazards in confined spaces that house electrical components or cabling, which, although unlikely, are prone to overheating or short circuits.
“Fires in batteries can lead to equipment damage, operational downtime, and serious safety risks,” adds Pagliarulo. “By automatically detecting and extinguishing fires within seconds at the source, the built-in fire extinguisher minimizes the risk of fire spreading, ensuring the protection of personnel and assets.”
In automotive applications, engineers are typically constrained by weight and packaging efficiency. However, the simplicity of a passive, thermally activated suppression mechanism may allow for integration without significant system redesign.

Flexible temperature-sensing tube used in the battery-integrated fire suppression system, designed to automatically release a clean extinguishing agent when critical temperatures are reached.
“Passenger EV engineers are typically more concerned with weight over space. However, the single tube with the fire-suppressant and a thermal sensor is small enough and can easily be fitted with a slight design change,” he says.
This suggests that similar systems could be adapted for use in EV battery packs, particularly as manufacturers continue to evaluate layered safety strategies that extend beyond monitoring and cooling.
The concept may also have relevance in smaller-format electrified systems, where battery enclosures are compact and failure tolerance is limited.
“A simple and reliable fire extinguisher adds value and can even be mandated for city e-mobility devices, at some point in the future,” Pagliarulo adds.
As battery systems increase in energy density across EV platforms, integrating passive safety mechanisms alongside active controls may become an area of greater interest. While implementation in automotive applications would require validation against stringent packaging, weight, and regulatory constraints, current deployments demonstrate how embedded fire suppression can function as a complementary safety layer within lithium battery systems.
“The Flexible Temperature-Sensing Self-Activating Fire Extinguishing Device is highly effective, with a tested fire extinguishing time of just 1.9 seconds. Its ability to detect and suppress fires quickly and autonomously significantly reduces the risk of fire-related incidents,” says Pagliarulo. “Additionally, its clean extinguishing agents are non-conductive and non-damaging to electrical equipment, ensuring minimal disruption to operations.”
Filed Under: Featured Contributions, Tech Spotlight, Thermal Management System